Questions & Answers
Copper bushings are made of: BrO10F1, M3, BrKMts3-1, M2r, BrAZh9-4, M2, BrOTsS5-5-5, M1r, M1, BrOF6.5-0.15.
Copper rods are made of: M3, M2r, M1r, M2, M1, M0.
Copper braids are made of: M2r, M2, M0, M1r, M1.
Copper strips are made of: M3, M2r, M2, M0, M1r, M1.
Copper foil is made of: M1r, M3, M2r, M2, M0, M1.
Copper tape is made of: M3, M0, M1r, M2, M1, M2r.
Copper tubes are made from: M2r, M1r, M3, M2, M1.
Copper ingots are made from: M3, M2, M1, M0, M2r, M1r.
Copper wire is made from: M3, M2r, M2, M1r, M1, M0, M1m, M1t.
Copper commutator profiles are made from: M2, M1r, M1, M0.
Copper round bars are made from: M3, M1r, M2, M1, M2r, M0.
Copper sheets are made from: M3, M1f, M2, M0, M1r, M0b, M00.
The main GOST standard for copper bushings:
GOST ISO 4379-2006 is a standard that regulates the tolerances, dimensions, and design of copper alloy bushings used in plain bearings. This standard defines: product interchangeability parameters, drawing designations, requirements for oil grooves and holes, design variants, tolerances, and geometric dimensions of the bushings.
The main GOST standard for copper rod:
GOST R 53803-2025 - specifications for copper rod for electrical purposes. This standard establishes: storage and packaging requirements, acceptance rules, testing methods, electrical characteristics, mechanical properties, chemical composition, and requirements for copper rod.
The main GOST standard for copper braid:
GOST 5349-76 - this standard defines the requirements for copper wire used to create braid. The standard regulates test methods, surface quality, electrical resistance, mechanical properties, wire diameter, and chemical composition of copper.
The main GOST for copper strip:
GOST 434-78 - Technical conditions for copper strip. This standard defines acceptance rules, packaging and marking, surface quality, test methods, electrical properties, tolerances, mechanical properties, copper grades, dimensions, and assortment.
The main GOST for copper tape:
GOST 1173-2006 - Technical conditions for copper tape. This standard establishes marking, copper grades, dimensions, assortment, tolerances, acceptance rules, packaging, test methods, surface quality, and mechanical properties.
The main GOST for copper tube:
GOST 617-2006 - Technical conditions for general-purpose circular copper tubes. This standard regulates surface quality, tolerances, packaging, marking, dimensions, product range, acceptance rules, testing methods, mechanical properties, and grades of copper pipes used in industry, refrigeration, plumbing, and power engineering.
The main GOST for copper foil:
GOST 5638-75 - Technical conditions for copper foil for technical purposes. This standard defines surface quality, testing methods, acceptance rules, dimensions, tolerances, thicknesses, marking, packaging, and the electrical and mechanical properties of copper foil used in printed circuit board manufacturing, electronics, radio engineering, and electrical engineering.
The main GOST for copper ingots:
GOST R 57376-2016 - Technical conditions for copper ingots. This standard defines requirements for the storage, appearance, copper quality, acceptance, transportation, marking, inspection methods, and chemical composition of copper ingots, ensuring the production of stable copper raw materials suitable for industrial processing.
The main GOST standard for copper wire is:
GOST 2112-79 - Specifications for round electrical copper wire. This standard regulates electrical resistance, dimensions, testing methods, diameters, copper grades, marking, surface quality, and mechanical properties of wire used in electrical engineering, power engineering, and the cable industry.
The main GOST standard for commutator profiles is:
GOST 25427-82 - Specifications for copper profiles for electrical machine commutators. This standard defines tolerances, inspection methods, marking, profile shapes, packaging, dimensions, and surface quality of profiles used in commutators of current-collecting systems and electrical machines.
The main GOST standard for copper round wires is:
GOST 1535-2016 - Specifications for copper rods. The standard establishes dimensional tolerances, mechanical properties, permissible diameters, packaging and marking, testing, acceptance rules, surface requirements, copper grades, production methods, and assortment of copper rods.
The main GOST for copper sheets:
GOST 1173-2006 - technical conditions for copper sheets. This standard regulates: storage and transportation, marking, packaging, testing rules, surface quality, material condition, mechanical properties, copper grades, tolerances, thicknesses, dimensions, and assortment of copper sheets.
Copper bushing weight chart
| External Ø × Internal Ø, mm | Weight of 1 m, kg |
| 10×6 | 0,26 |
| 12×8 | 0,34 |
| 14×10 | 0,42 |
| 16×10 | 0,61 |
| 18×12 | 0,69 |
| 20×12 | 0,86 |
| 20×14 | 0,69 |
| 22×16 | 0,79 |
| 25×15 | 1,23 |
| 25×18 | 0,97 |
| 28×20 | 1,14 |
| 30×20 | 1,48 |
| 30×22 | 1,24 |
| 35×25 | 1,66 |
| 40×30 | 1,77 |
| 45×35 | 1,91 |
| 50×40 | 1,98 |
Copper rod weight chart
| Diameter, mm | Weight of 1 m, kg |
| 2 | 0,028 |
| 3 | 0,063 |
| 4 | 0,113 |
| 5 | 0,176 |
| 6 | 0,254 |
| 8 | 0,452 |
| 10 | 0,707 |
| 12 | 1,018 |
| 14 | 1,386 |
| 16 | 1,81 |
| 18 | 2,29 |
| 20 | 2,826 |
| 22 | 3,419 |
| 25 | 4,398 |
| 28 | 5,502 |
| 30 | 6,362 |
| 32 | 7,258 |
| 35 | 8,586 |
| 40 | 11,304 |
| 45 | 14,361 |
| 50 | 17,662 |
Copper braid weight chart
| Cross-section (equivalent mm²) | Width, mm | Thickness, mm | Weight of 1 m, kg |
| 10 | 5 | 1.5 | 0,09 |
| 16 | 6 | 1.8 | 0,14 |
| 25 | 8 | 2.0 | 0,22 |
| 35 | 10 | 2.2 | 0,31 |
| 50 | 12 | 2.5 | 0,44 |
| 70 | 15 | 3.0 | 0,62 |
| 95 | 18 | 3.5 | 0,84 |
| 120 | 20 | 4.0 | 1,06 |
| 150 | 25 | 4.5 | 1,32 |
| 185 | 30 | 5.0 | 1,63 |
| 240 | 35 | 6.0 | 2,12 |
| 300 | 40 | 7.0 | 2,65 |
Copper strip weight table
| Size, mm (width × thickness) | Weight of 1 m, kg |
| 10 × 2 | 0,18 |
| 15 × 2 | 0,27 |
| 20 × 2 | 0,36 |
| 20 × 3 | 0,53 |
| 25 × 3 | 0,67 |
| 30 × 3 | 0,8 |
| 30 × 4 | 1,07 |
| 40 × 4 | 1,42 |
| 40 × 5 | 1,78 |
| 50 × 5 | 2,23 |
| 60 × 5 | 2,67 |
| 60 × 6 | 3,2 |
| 80 × 6 | 4,27 |
| 100 × 6 | 5,34 |
| 100 × 8 | 7,12 |
| 120 × 10 | 10,68 |
Copper tape weight chart
| Width × Thickness, mm | Weight of 1 m, kg |
| 10 × 0.1 | 0,009 |
| 10 × 0.2 | 0,018 |
| 15 × 0.2 | 0,027 |
| 20 × 0.2 | 0,036 |
| 20 × 0.3 | 0,053 |
| 25 × 0.3 | 0,067 |
| 30 × 0.3 | 0,08 |
| 40 × 0.5 | 0,178 |
| 50 × 0.5 | 0,223 |
| 60 × 0.5 | 0,267 |
| 80 × 0.8 | 0,57 |
| 100 × 1.0 | 0,89 |
| 120 × 1.0 | 1,068 |
| 150 × 1.5 | 2,003 |
| 200 × 2.0 | 3,56 |
Copper pipe weight chart
| Outside diameter × Wall thickness, mm | Outside diameter × Wall thickness, mm |
|---|---|
| 6 × 1 | 0,14 |
| 8 × 1 | 0,2 |
| 10 × 1 | 0,25 |
| 12 × 1 | 0,31 |
| 15 × 1 | 0,39 |
| 15 × 1.5 | 0,55 |
| 18 × 1 | 0,48 |
| 18 × 1.5 | 0,67 |
| 22 × 1 | 0,59 |
| 22 × 1.5 | 0,82 |
| 28 × 1 | 0,76 |
| 28 × 1,5 | 1,05 |
| 35 × 1.5 | 1,34 |
| 42 × 1.5 | 1,63 |
| 54 × 2 | 2,9 |
| 76 × 2 | 4,12 |
| 89 × 2 | 4,86 |
| 108 × 2.5 | 7,35 |
Copper foil weight chart
| Thickness, mm | Weight of 1 m², kg |
| 0.01 | 0,089 |
| 0.015 | 0,134 |
| 0.02 | 0,178 |
| 0.03 | 0,267 |
| 0.05 | 0,445 |
| 0.08 | 0,712 |
| 0.1 | 0,89 |
| 0.15 | 1,335 |
| 0.2 | 1,78 |
| 0.3 | 2,67 |
| 0.5 | 4,45 |
| 1.0 | 8,9 |
Copper ingot weight chart
| Type of pig | Size/shape | Weight of 1 piece, kg |
| Copper cathode | sheets/plates | 40–80 |
| Copper anode | plate | 60–120 |
| Cast pig | standard ingot | 15 |
| Cast pig | standard ingot | 25 |
| Cast pig | standard ingot | 30 |
| Cast pig | standard ingot | 40 |
| Industrial pig iron | large ingot | 80 |
| Industrial pig iron | large ingot | 100 |
| Export pig iron | standard | 110 |
| The pig is heavy | metallurgical | 125 |
| The pig is heavy | metallurgical | 150 |
| Large pig | smelting | 200 |
| Extra large pig | industrial | 250 |
Copper wire weight chart
| Diameter, mm | Area, mm² | Weight of 1 m, kg |
| 0.5 | 0.2 | 0,0018 |
| 0.8 | 0.5 | 0,0045 |
| 1.0 | 0.79 | 0,007 |
| 1.2 | 1.13 | 0,01 |
| 1.5 | 1.77 | 0,0158 |
| 2.0 | 3.14 | 0,028 |
| 2.5 | 4.91 | 0,0437 |
| 3.0 | 7.07 | 0,063 |
| 4.0 | 12.57 | 0,112 |
| 5.0 | 19.63 | 0,175 |
| 6.0 | 28.27 | 0,252 |
| 8.0 | 50.27 | 0,447 |
| 10 | 78.54 | 0,698 |
Collector profile weight table
| Width × Thickness, mm | Weight of 1 m, kg |
| 5 × 3 | 0,133 |
| 6 × 3 | 0,16 |
| 8 × 3 | 0,213 |
| 10 × 3 | 0,267 |
| 10 × 4 | 0,356 |
| 12 × 4 | 0,427 |
| 15 × 4 | 0,534 |
| 15 × 5 | 0,668 |
| 20 × 4 | 0,712 |
| 20 × 5 | 0,89 |
| 25 × 5 | 1,112 |
| 30 × 5 | 1,335 |
| 30 × 6 | 1,602 |
| 40 × 6 | 2,136 |
| 50 × 6 | 2,67 |
Copper circle weight table
| Diameter, mm | Weight of 1 m, kg |
| 5 | 0,175 |
| 6 | 0,252 |
| 8 | 0,447 |
| 10 | 0,698 |
| 12 | 1,006 |
| 14 | 1,365 |
| 16 | 1,789 |
| 18 | 2,266 |
| 20 | 2,792 |
| 22 | 3,38 |
| 25 | 4,35 |
| 28 | 5,495 |
| 30 | 6,32 |
| 32 | 7,188 |
| 35 | 8,66 |
| 40 | 11,16 |
| 45 | 14,16 |
| 50 | 17,45 |
| 60 | 25,13 |
| 70 | 34,19 |
| 80 | 44,6 |
| 90 | 56,39 |
| 100 | 69,8 |
Copper sheet weight table
| Sheet thickness, mm | Weight of 1 m², kg |
| 0.3 | 2.68 |
| 0.4 | 3.57 |
| 0.5 | 4.47 |
| 0.6 | 5.36 |
| 0.8 | 7.14 |
| 1.0 | 8.93 |
| 1.2 | 10.72 |
| 1.5 | 13.4 |
| 2.0 | 17.86 |
| 2.5 | 22.33 |
| 3.0 | 26.79 |
| 4.0 | 35.72 |
| 5.0 | 44.65 |
| 6.0 | 53.58 |
| 8.0 | 71.44 |
| 10 | 89.3 |
| 12 | 107.16 |
| 15 | 133.95 |
| 20 | 178.6 |
| 25 | 223.25 |
| 30 | 267.9 |